0102030405
SDL/SDW Single stage single suction centrifugal pump
Dry abrasion resistance
The machine seal can dry grind for more than 8 hours without water
Energy-saving
Energy-saving electric motor+High efficiency hydraulic design
Fast self-priming
Professional mechanical design+Precision manufacturing
Low noise
Smooth operation +Excellent fluid performance
Strong protection
IP55 or above protection level
High intelligence
AI intellisense +AIOPS


SINGLE STAGE SINGLE SUCTION CENTRIFUGAL PUMP


Change machine seal less,save money and trouble
machine seal is no longer CONSUMABLE
Not afraid of water dry grinding
We have a patent for the sealing structure ,ensure that the machine can be sealed and dried for more than 8 hours in the state of water shortage ,reduce the machine seal replacement rating!

Reduce burn probability and extend life
Reduce user purchase cost!
High temperature grease
Customized high temperature grease to match high temperature electric motor,it can reduce the probability of bearing damage and stuck caused by high temperature and over load!

Class H electric motor
SEAD Class H insulated electric motor,increase the temperature resistance of the industry’s common class F insulated electric motor from 150℃ to 180℃!

Enery-saving design ,relieved to use!
Reduce user costs!
High-efficiency energy-saving electric motor
GB standard motor, YE3/YE4 energy-saving motor,explosion-proof motor and variable frequency motor are optional,Ultra energy-saving, and can be used without concern!

Advanced hydraulic design
Adopt flow field LVD and PIV technology,CFD design for excellent water,designed for superior hydraulic performance it ensures the high energy efficiency of the pump!

Super protection,strong adaptability
Can easily cope with harsh environments!
Class IP55
IP55 electric motor is waterproof and dust-proof. Regardless of outdoor wind and rain ,indoor dust and other harsh environment ,please feel free to use it!

Precision manufacturing,quiet work
Create a quiet environment !
Digital manufacture
Structural design stability can reduce mechanical noise ,durable lubrication can reduce rotation noise , CFD design reduces fluid noise!

Strong self-suction ,Pumping water quickly
Cure anxiety!
The small impeller clearance
High precision and dynamic equilibrium can ensure the precision clearance between the impeller and the water inlet or baffle tongue to improve its own performance!

Spray coating,environment protection and anti-corrosion!
Stunning visual effects!
Anti-corrosion and wear resistance
Spray color variety,coating adhesion,corrosion resistance,aging resistance and nontoxic volatilization.It can be washed as new in the rain!

Flexible application
Two forms of worry-free choice
Two models are available, vertical and hor-izontal, to meet the needs of different users and different scenarios.

Application scenarios
Single-stage single-suction centrifugal pump is a common fluid transfer equipment, which is widely used in many fields such as industry, construction, agriculture and municipal, and the following are some specific application scenarios:



Single-stage single-suction centrifugal pump |
Basic type |
Intelligent type |
||
APPEARANCE |
Product color |
Dark black+Deep sea blue |
Dark black+Deep sea blue |
|
Installation dimension |
See product description for details |
See product description for details |
||
Product packaging |
Plywood box(yellow)/Carton |
Plywood box(white) |
||
CONFIGURATION |
Electrical motor |
GB standard |
Variable frequency / Energy-saving |
|
Bearing |
C&U |
C&U/NSK/SKF |
||
Shaft |
304 stainless steel |
304 stainless steel |
||
Machine seal |
Ordinary |
Dry abrasion- resistant |
||
Materials |
Cast iron |
Cast iron/QT450/304# |
||
Parameter |
Pump efficiency |
|
|
|
Energy efficiency |
IE3 |
IE2 |
||
Insulation |
Class F |
Class H |
||
Grease temperature |
-20~+150℃ |
-20~+180℃ |
||
Protection class |
IP55 |
>IP55 |
||
Noise |
< |
< |
||
After-sales service |
The main components come with a one-year warrant |


Warning:Make sure the power is disconnected before remov-ing or adjusting the junction box and the pump.The external power switch connected to the pump motor has a minimum electrode gap of 3mm.
The voltage and frequency of the power supply should conform to the indicated value on the pump nameplate to ensure that the power supply meets the require- ments of use.Install and ground accurately according to the wiring method indicated on the junction box(shown on the right).
Note:Recommended 11kw and below starts directly,11-75kw starts with Star-Delta Starting mode.75-400kw starts with Soft Starting mode.In ad-dition,the 45-200kw can also start with Autotransformer Start mode.The starting method is not unique,please consult a professional.
(Two)Rotation direction check
Seen from the fan cover,the rotating arrow rotates clock-wise,As shown at right.
Caution!
Do not start the pump to check the direction of motor rotation until the pump boby is filled with liquid and removes air
Before connecting the pump to the pipe,the direction must first be determined by the flow
arrow on the pump head.To ensure the tightness of the pipeline connection,please install rubber washer or other Sealing material between flanges.As shown at right.