Leave Your Message
Fill in your information and unlock the Pump Catalog and the complete set of technical data immediately!
ZW Non-clogging self priming sewage pump

Non-clogging self priming sewage pump

ZW Non-clogging self priming sewage pump

1,For the industry pain points, reduce common faults (for common faults, solve the industry pain points) which is more sales force?

  Ⅰ. Wear resistant seal

       The exclusive patented mechanical seal structure design, can not fail in the case of continuous no-load operation of the pump for 8 hours,greatly reduce the industry's

       number one sealing failure - leakage failure rate and frequency of replacement of wearing parts

  Ⅱ. High temperature lubricating grease: equipped with brand bearings, customized high temperature lubricating grease, reduce the industry failure rate ranked second

       bearing failure rate!

  Ⅲ. Class H insulation: Better high temperature resistance and insulation performance, reducing the failure rate of the industry ranking third, the biggest loss of the machine

       failure rate!

  Ⅳ. Double channel impeller

       High pass rate performance reduces blockage

2.Energy-efficient

  Ⅴ.Energy-efficient motors

      Save energy and reduce costs in long term

  Ⅵ.Professional hydraulic optimization

      Pump head and impeller use professional CFD hydraulic analysis, and scientific optimization treatment, greatly improving the compatibility and hydraulic performance

  Ⅶ.Reasonable structure: Professional mechanical structure design, high-precision processing guarantee, digital factory manufacturing, to ensure that the mechanical loss is minimized

3.Increase service life

   Ⅷ. Super protection design: the protection level far exceeds IP55, can adapt to a variety of harsh environments

   Ⅸ. Stainless steel coupled

         Improve anti-rust ability of shaft, extend the service life of pump

  Ⅹ. Bearing pressure plate design

       Prevent bearing movement, improve bearing life, ensure motor stable operation 

4.Environmental protection safety

   Ⅹ. Spray coating process below 7.5kw and including 7.5kw

        No pollution to the environment, no toxicity to the human body, coating appearance quality is excellent, strong adhesion




    Easy disassembly
    Easy disassembly and can be equipped with various motors

    Energy-saving
    Efficient and energy-saving motor+efficient hydraulic design

    Anti-corrosion
    All castings are treated by electrophoresis

    Ultra-low mute
    stable operation+Excellent fluid performance

    Intelligence upgrading
    AI Intelligent perception of private domain+Intelligent operation and maintenance
    ZW Non-clogging self priming sewage pump (1)ZW Non-clogging self priming sewage pump (2)

    Non-clogging self priming sewage pump

    ZW Non-clogging self priming sewage pump (3)ZW Non-clogging self priming sewage pump (4)

    Mechanical seal for dry grinding with water shortage

    Derived from the patented sealing structure technology of SEAD, the mechanical seal can undergo dry grinding for more than 8 hours without failure under the condition of water shortage.lt reduces the replacement frequency of the me-chanical seal and makes the mechanical seal no longer a "wearing part"!
    ZW Non-clogging self priming sewage pump (6)

    Dirt is not easily clogged

    The double-channel impeller has a high passage rate for dirt!
    ZW Non-clogging self priming sewage pump (8)

    Fast self-priming and sewage discharge function

    High precision and dynamic balance ensure the clearance between the impeller and the water inlet or cutwater, which improves the self-priming performance!
    ZW Non-clogging self priming sewage pump (10)

    Durable and long -lasting

    1. Class H insulation, customized high-temperature lubricating grease and bearings are used to reduce the probability of motor burnout!
    2. lt features super-strong protection that far exceeds lP55 and can adapt to a variety of harsh environments!
    3. The stainless steel coupling shaft enhances the rust resis-tance of the shaft and extends the service life of the pump!
    4. The design of the bearing pressure plate prevents the axial movement of the bearing,improves the service life of the bearing and ensures the stable operation of the motor!
    ZW Non-clogging self priming sewage pump (12)

    High efficiency and energy saving

    It is equipped with SEAD standard full-power energy-sav-ing motors and outstanding hydraulic models, featuring powerful driving force and worry-free sewage discharge!
    ZW Non-clogging self priming sewage pump (14)

    Environmentally and safe

    Pumps with a power of 7.5 kW and below adopt the plastic spraying coating process on the surface. lt causes no pollution to the environment, is non-toxic to human bodies, and has ex-cellent appearance quality of the coating with strong adhe
    ZW Non-clogging self priming sewage pump (16)

    Intelligent operation and maintenance

    It can be equipped with SEAD Digital Intelligence System to realize intelligent perception, intelligent monitoring,and intelligent operation and mainte-nance of the product!
    ZW Non-clogging self priming sewage pump (18)

    Application scenarios

    Non-clogging self priming sewage pump is a common fluid transfer equipment, which is widely used in many fields such as industry, construction, agriculture and municipal, and the following are some specific application scenarios:
    ZW Non-clogging self priming sewage pump (20)ZW Non-clogging self priming sewage pump (21)ZW Non-clogging self priming sewage pump (22)

    Non-clogging self priming sewage pump

    Basic type

    Wear-resistant type

    Intelligent type

     

    APPEARANCE

    Product color

    Dark black+Deep sea blue

    Dark black+Deep sea blue

    Dark black+Deep sea blue

    Installation dimension

    See product description for details

    See product description for details

    See product description for details

    Product packaging

    Plywood box(yellow)/Carton

    Plywood box(white)

    Plywood box(white)

    CONFIGURATION

    Electrical

    motor

    GB standard

    GB standard /Energy-saving

    Variable frequency / Energy-saving

    Bearing

    C&U

    C&U/NSK/SKF

    C&U/NSK/SKF

    Shaft

    304 stainless steel

    304 stainless steel

    304 stainless steel

    Machine seal

    Ordinary

    Dry abrasion- resistant

    Dry abrasion- resistant

    Materials

    Cast iron

    Cast iron

    Cast iron

    Parameter

    Pump

    efficiency

     

     

     

    Energy efficiency

    IE3

    IE3

    IE2

    Insulation 

    Class F

    Class H

    Class H

    Grease temperature

    -20~+150℃

    -20~+180℃

    -20~+180℃

    Protection class

    IP55

    >IP55

    >IP55

    Noise

    After-sales service

    The main components come with a one-year warrant

    ZW Non-clogging self priming sewage pump (23)ZW Non-clogging self priming sewage pump (24)
    Warning:Make sure the power is disconnected before remov-ing or adjusting the junction box and the pump.The external power switch connected to the pump motor has a minimum electrode gap of 3mm.

    The voltage and frequency of the power supply should conform to the indicated value on the pump nameplate to ensure that the power supply meets the require- ments of use.Install and ground accurately according to the wiring method indicated on the junction box(shown on the right).

    Note:Recommended 11kw and below starts directly,11-75kw starts with Star-Delta Starting mode.75-400kw starts with Soft Starting mode.In ad-dition,the 45-200kw can also start with Autotransformer Start mode.The starting method is not unique,please consult a professional.

    (Two)Rotation direction check
    Seen from the fan cover,the rotating arrow rotates clock-wise,As shown at right.

    Caution!
    Do not start the pump to check the direction of motor rotation until the pump boby is filled with liquid and removes air

    Before connecting the pump to the pipe,the direction must first be determined by the flow
    arrow on the pump head.To ensure the tightness of the pipeline connection,please install rubber washer or other Sealing material between flanges.As shown at right.